On the contrary, if the pole distance is higher than 4.scm., the effect of increasing the pole distance on the current efficiency becomes less and less obvious(oem white aluminum oxide and brown aluminium oxide). After the molecular ratio is reduced, electrolysis operators are often faced with two choices, either to reduce the pole pitch to maintain the cell voltage, or to maintain the pole pitch to increase the fine voltage(aluminum oxide sandblasting).


OEM White Aluminum Oxide and Brown Aluminium Oxide MOQ: 1 Ton! 19 Years OEM White Aluminum Oxide and Brown Aluminium Oxide Experience, 35,000m² Workshop Area, Free Samples, Fast Delivery!


If you want to oem white aluminum oxide and brown aluminium oxide, please click our products: Brown Fused Alumina or White Fused Alumina for more information!


In other words, from the perspective of calculating energy consumption, some companies define the average voltage (or statistical average voltage) as(garnet sand): Pamee refers to the first trough column bus bar in the plant from the rectifier station, and the last trough bus bar convergence point to the rectifier station(oem white aluminum oxide and brown aluminium oxide). The cell voltage regulation in production means that the cell voltage is changed by adjusting the pole distance(aluminium oxide abrasive grit).


According to the total voltage obtained by the rectifier station and the electrolysis computer room, the statistics department calculates a ratio, namely Pemnwa/Pwmmanm(aluminium oxide grit suppliers). Vemsa refers to the apportionment value of the voltage value consumed by the parked bus in the series on the series production tank. The change of pole distance by LMM causes the change of cell voltage by about 30-40mv, which is very significant(oem white aluminum oxide and brown aluminium oxide).


Therefore(150 grit aluminum oxide), some companies define the average voltage as(oem white aluminum oxide and brown aluminium oxide): the daily average value of plant working voltage + the voltage drop on the external bus (mainly from the rectifier car to the connecting bus of the electrolysis workshop, and the double-pressing bus passing through the aisle of the electrolysis workshop) (Daily average) + anode effect apportioned voltage (daily apportionment)(aluminum oxide suppliers usa). The less white corundum, the better the matte effect.


Because of the large number of electrode blocks of pre culture essence, it is difficult to keep each anode at the same electrode distance(silicon carbide grit). This is why the concepts of pole distance regulation and slot voltage regulation are often equated in production. Adding some white corundum still wants to improve the shot peening efficiency and eliminate the slight scratches on the stainless steel surface faster(oem white aluminum oxide and brown aluminium oxide).


Finally, shunshi pointed out that although it is difficult to reduce the vertebral temperature significantly, low-temperature aluminum electrolysis is still the goal of the aluminum industry(oem white aluminum oxide and brown aluminium oxide). At the end of each month, the manager shall determine the target value that can be achieved through efforts according to the operation and operation of the tank(alumina grit). It does not include the effect voltage apportionment value. 


When formulating various voltage benchmarks(green silicon carbide), factory managers should grasp the dialectical relationship between phase voltage and other technological conditions and technical and economic indicators, and grasp some important concepts, such as the influence of changes in electrolyte composition on operating voltage(aluminium oxide suppliers south africa). The control machine (computer) controls the operating voltage with the set voltage as the target(oem white aluminum oxide and brown aluminium oxide).


Average voltage: In some control systems, the daily average value of the full voltage is often called the daily average voltage, or simply average voltage(alumina abrasive). Theoretical calculations for large-scale pre-cultivation test show that if the pole pitch is to be kept constant, the set working voltage should be increased by about 50mV every time the numerator ratio is reduced by 0.1(oem white aluminum oxide and brown aluminium oxide). Also known as the black voltage coefficient.


The difference between several working voltages and the set voltage reflects whether there is an abnormal voltage on site(aluminum oxide blast media canada), and the difference between 0 and 003V indicates that the voltage is well controlled(oem white aluminum oxide and brown aluminium oxide). Therefore, if the working voltage when the numerator ratio is 26 is 40V, then When the numerator ratio is adjusted to 2.3, the set working voltage should be adjusted to 4.15V to keep the pole pitch from shrinking.


The traditional electrolysis process maintains a high effect coefficient (about 1.0), which is limited by the past automatic control technology and anode quality(pink corundum), on the one hand, and based on the understanding of the effect(oem white aluminum oxide and brown aluminium oxide). The shared value of the voltage drop consumed by the busbars connected between the various areas of the factory and the busbars between the factory buildings on the series production profile(white aluminum oxide blast media).


At the same time, increasing the electrode distance on the one hand can reduce the dissolution loss of aluminum in the electrolyte, which is beneficial to improve the current efficiency(120 grit aluminum oxide blasting media); on the other hand, it is unfavorable to reduce the energy consumption index by increasing the electrolyte voltage drop and increasing the cell voltage(oem white aluminum oxide and brown aluminium oxide). Therefore, there is a problem of how to select the best polar distance in production.


It is also possible that due to the excessive increase in energy income, the purpose of lowering the temperature cannot be achieved in fact(oem white aluminum oxide and brown aluminium oxide). The research shows that when the pole distance is less than 4cm(80 grit aluminum oxide blasting media), the effect of increasing the pole distance on the current efficiency is very obvious, and the effect of improving the current efficiency on reducing energy consumption is greater than that of increasing the cell voltage.


The industrial site does not detect the pole distance or set the reference value of the pole distance(corundum sand), but sets the best voltage value to ensure that the pole distance is high enough(oem white aluminum oxide and brown aluminium oxide). Therefore, the benefits of improving the current efficiency can not offset the disadvantages caused by increasing the cell voltage (thus increasing the cell temperature). Adjusting the pole distance is the main means to adjust the slot voltage(100 grit aluminum oxide).


The electrode distance of pre culture is generally higher than that of self culture box(black aluminum oxide). There shall be no carbon blocks with too low polar distance, which will cause uneven current distribution, local overheating, voltage swing, anode block falling and reduce current efficiency(oem white aluminum oxide and brown aluminium oxide). The general setting voltage is the operating voltage control target set by the manager for each error control machine of the electrolytic cotton.


The working voltage (or net voltage) refers to the voltage drop between the incoming and outgoing terminals of the electrolytic cell(glass bead blasting media suppliers), which is also the cell voltage actually controlled by the inspection and control machine(oem white aluminum oxide and brown aluminium oxide). In addition, the setting of vibration and swing criteria of some resistance meters is also important(abrasive blast media), because the stability of resistance can reflect whether the setting of pole distance is high enough.


Slot voltage management involves the following four voltages with different meanings(steel grid): target voltage, which is an index set for daily standard management of voltage(oem white aluminum oxide and brown aluminium oxide). It is composed of back electromotive force (including theoretical decomposition voltage and cathode and rigid pole overvoltage), electrolyte voltage drop, anode voltage drop, cathode voltage drop (furnace bottom voltage drop) and bus voltage drop.


Based on the above analysis(aluminium oxide powder), it can be seen that the pole pitch adjustment (or cell voltage adjustment) needs to have two purposes(oem white aluminum oxide and brown aluminium oxide): one is to maintain a sufficiently high pole pitch; the other is to maintain a suitable cell voltage to maintain a suitable energy income (and ultimately maintain the energy of the electrolytic cotton balance). The full voltage is the sum of the working voltage and the effect sharing voltage(aluminium oxide blast media).


white aluminium oxide
Contact Us
  • Contact:Terry
  • Tel:0086-15515998755
  • Wechat:Wilson15515998755
  • Whatsapp:0086-15515998755
  • Email:terry@wilsonabrasive.com
Follow Us

Wilson Abrasive CO.,LTD Copyright © 2002-2021 All Rights Reserved. sitemap

Brown Fused Alumina And White Fused Alumina MOQ: 1 Ton! 19 Years Manufacturing Exprience, 35,000m² Workshop Area, Factory Price, Free Samples, Fast Delivery!

no cache
Processed in 1.325402 Second.